Page 3 - VESBO Corrugated Brochure
P. 3

Properties of VESBO Corrugated Pipes                                              Dimensions


      VESBO Corrugated pipes are classified according to their ring stiffness.           DN / ID  SN    Length (m)  d e (mm)  d i (mm)
                                                                                          (mm)
      Rigidity is the measurement of resistance of the pipe against ring                  100     4 8    6. 7  118-119  100.0-101.1
                                                                                                  4
      deformation. Pipes are designed so as to balance the outer loads when laid          150     8      6. 7  176-177  150.0-152.8
                                                                                                  4                   199.0-199.5
      under ground. VESBO Corrugated Pipes are available as SN4 and SN8. Pipes            200     8      6. 7  230-231  197.5-199.0
                                                                                                  4                   298.0-299.0
                                                                                          300            6. 7  344-345
      with rigidity value SN4 can take of max. 4.0 kN/m² and with rigidity value                  8                   297.0-298.0
                                                                                          400     4      6. 7  465-466  398.0-399.0
      SN8 max. loads of 8.0 kN/m².                                                                8                   397.0-398.0
                                                                                          500     4      6. 7  585-587  498.0-499.0
                                                                                                  8                   497.0-498.0
      • SN4 (4.0 kN/m² = 400 kg/m²) for off traffic areas and                           Installation of VESBO Corrugated Pipes
      • SN8 (8.0 kN/m² = 800 kg/m²) for areas with traffic load should be

        preferred.                                                                      Distance
                                                                                        between the                                                Decompressed area of
                                                                                                                                                   soil
                                                                                        ground to                               Final Backfill
                                                                                        the top of
                                                                                        the pipe
      VESBO Corrugated Pipes are produced according to EN 13476-3+A1                                                          Between 100mm and 300mm
                                                                                                                                                   Region where all solid
      standard and during the production process they are subject to below given                                                                   particles are removed
                                                                                                                                Initial Backfill
      tests performed periodically.
                                                                                                                                                   Decompressed area of
                                                                                        Y = min                                                    sand
                                                                                        100mm                                   Bedding Layer
      Test Results of VESBO Corrugated Pipes                                                                                    Natural Soil

                                                                                                      Width of the trench
             Test Name         Test Method  Unit   Result
      Density Test             ISO 1183    kg/m³.  > 930
      Mass Melt Flow Rate Test  ISO 1133  g/ 10 min.  < 1.6
      Thermal Strength-Oven Test  ISO 12091  -    Suitable
      Ring Rigidity            ISO 9969    kN/ m³  < SN value
      Ring Flexibility         EN 13968      -    Suitable
      Impact Resistance        ISO 3127      -    Suitable
      Water Impermeability Test   ISO 13254  -    Suitable
                  (0.5 bar.1 min.)
      Internal Pressure Resistance   ISO 1167  -  Suitable
          (165 and 1000 hours at 80°C)
   1   2   3   4   5