Page 3 - VESBO Corrugated Brochure
P. 3
Properties of VESBO Corrugated Pipes Dimensions
VESBO Corrugated pipes are classified according to their ring stiffness. DN / ID SN Length (m) d e (mm) d i (mm)
(mm)
Rigidity is the measurement of resistance of the pipe against ring 100 4 8 6. 7 118-119 100.0-101.1
4
deformation. Pipes are designed so as to balance the outer loads when laid 150 8 6. 7 176-177 150.0-152.8
4 199.0-199.5
under ground. VESBO Corrugated Pipes are available as SN4 and SN8. Pipes 200 8 6. 7 230-231 197.5-199.0
4 298.0-299.0
300 6. 7 344-345
with rigidity value SN4 can take of max. 4.0 kN/m² and with rigidity value 8 297.0-298.0
400 4 6. 7 465-466 398.0-399.0
SN8 max. loads of 8.0 kN/m². 8 397.0-398.0
500 4 6. 7 585-587 498.0-499.0
8 497.0-498.0
• SN4 (4.0 kN/m² = 400 kg/m²) for off traffic areas and Installation of VESBO Corrugated Pipes
• SN8 (8.0 kN/m² = 800 kg/m²) for areas with traffic load should be
preferred. Distance
between the Decompressed area of
soil
ground to Final Backfill
the top of
the pipe
VESBO Corrugated Pipes are produced according to EN 13476-3+A1 Between 100mm and 300mm
Region where all solid
standard and during the production process they are subject to below given particles are removed
Initial Backfill
tests performed periodically.
Decompressed area of
Y = min sand
100mm Bedding Layer
Test Results of VESBO Corrugated Pipes Natural Soil
Width of the trench
Test Name Test Method Unit Result
Density Test ISO 1183 kg/m³. > 930
Mass Melt Flow Rate Test ISO 1133 g/ 10 min. < 1.6
Thermal Strength-Oven Test ISO 12091 - Suitable
Ring Rigidity ISO 9969 kN/ m³ < SN value
Ring Flexibility EN 13968 - Suitable
Impact Resistance ISO 3127 - Suitable
Water Impermeability Test ISO 13254 - Suitable
(0.5 bar.1 min.)
Internal Pressure Resistance ISO 1167 - Suitable
(165 and 1000 hours at 80°C)