Page 3 - INCOLA Inferno Brochure
P. 3

INCOLA Inferno

                                                                                          Fireproof !


     Preferred in:


         Hotels and Resorts
                                                                                          INCOLA Inferno        Talk                Plane Take-Off
         Residences                                                                       16 dB(A)              40-60 dB(A)         120-140 dB(A)


          Highrise Buildings



         Hospitals and Laboratories


         Schools
                                                                                                   Whisper                Yell               Gun Shot (Short Distance)
                                                                                                   30 dB(A)               80-90 dB(A)        130 dB(A)
         Sustainable / Green Buildings


                                                                                        The table below shows result of the test reports (P-BA 139/2018e) made by ’’Fraunhofer’’ Institute in
     Advantages                                                                         Stuttgart for Building Physics IBP on 25th April, 2018 in accordance with the DIN 4109 plant
                                                                                        engineering scheme and EN 14366.
         Excellence Sound Insulation
                                                                                                                               Test Results vs. Flow Rates (l/s)
                                                                                        Noise Level Types
                                                                                                                               0.5    1     2      4
                                                                                                                  1
         Fire Safety                                                                    Airborne sound pressure level  , [dB(A)] in the   43  47  49  52
                                                                                        basement test room UG front
                                                                                                                          1
                                                                                        Structure-borne sound characteristic level  , [dB(A)] in   <10  <10  11  16
                                                                                        the basement test room UG rear
          Indoor and Outdoor Use                                                        Installation sound level   [dB(A)] measured in the
                                                                                                             2
                                                                                        basement test room UG front            43    47     49    52
                                                                                                             2
                                                                                        Installation sound level   [dB(A)] measured in the   <10  10  14  19
                                                                                        basement test room UG rear
                                                                                                             1
         Ease of Installation                                                           Installation sound level   [dB(A)] measured in the   40  45  47  49
                                                                                        basement test room UG front
                                                                                        Installation sound level   [dB(A)] measured in the   <10   <10  10  16
                                                                                                             1
                                                                                        basement test room UG rear
         Smooth Inner Surface
                                                                                        1  According to EN 14366,  According to DIN 4109,  According to VDI 4100
                                                                                                                            3
                                                                                                          2
         Eco-friendly
   1   2   3   4