Page 10 - INCOLA EXCLUSIVE DATA CATALOGUE
P. 10

System Analysis






                1.5 VESBO INCOLA Inferno



                "Fireproof Silence!"
                   Inferno, provides the best non flammability feature among all INCOLA Soundproof Piping
                   Systems.


                                                                                 Pipe Diameter        Wall Thickness
                                                                                             (mm)         (mm)
                                           Inner Layer   :  Abrasion resistant and smooth
                                                     inner surface - PP              Ø50           4.0
                                                                                     Ø75           4.5
                                           Middle Layer :  Sound absorbing and fire-retardant
                                                     Incolene material               Ø110          5.3
                                           Outer Layer  :  Nonflammable PP           Ø125          5.3
                                                                                     Ø160          5.3
                                                                                     Ø200          6.2





                                  16 dB(A) according to EN 14366.



                                  Fire behavior  level is  BS2d0 according to  EN 13501-1. Fire status is  B1
                                  according to DIN 4102.


                                  Up to maximum  95°C long term usage, up to maximum  110°C short term
                                  usage.



                                  Halogen-free.

                    No Flame Transmission


                                  Suitable for transportation of wastewater (pH” range 2 to 12)



             The table below shows the test report results (number P-BA 139/2018e) performed on April 25, 2018
                                                                       -
             for VESBO INCOLA Inferno by Fraunhofer Institute for Building Physics:

                                                                             Test Results vs. Flow Rates(l/s)
            Noise Level Types
                                                                              0.5      1        2       4
            Installation sound level L  [dB(A)]  measured in the basement test room UG front  43  47  49  52
                                    1
                              in
            Installation sound level L  [dB(A)]  measured in the basement test room UG rear  <10  <10  14  19
                                    1
                              in
                                    2
            Installation sound level L  [dB(A)]  measured in the basement test room UG front  40  45  47  49
                              in
                                    2
            Installation sound level L  [dB(A)] measured in the basement test room UG rear  <10  <10  <10  16
                              in
                                          3
            Airborne sound pressure level L a,A  [dB(A)]  in the basement test room UG front  43  47  49  52
                                                  3
            Structure-borne sound chracteristic level L sc,A  [dB(A)]  in the basement test room UG rear  <10  <10  11  16
             Table 3. Sound Insulation Results for VESBO Incola Inferno in accordance with DIN 4109, VDI 4100 and EN 14366 Standards
              Evaluation according to DIN 4109,  Evaluation according to VDI,   Evaluation according to EN 14366
             1                     2                  3
                                                           08
   5   6   7   8   9   10   11   12   13   14   15