System Analysis
1.5 VESBO INCOLA Inferno
"Fireproof Silence!"
Inferno, provides the best non flammability feature among all INCOLA Soundproof Piping
Systems.
Pipe Diameter Wall Thickness
(mm) (mm)
Inner Layer : Abrasion resistant and smooth
inner surface - PP Ø50 4.0
Ø75 4.5
Middle Layer : Sound absorbing and fire-retardant
Incolene material Ø110 5.3
Outer Layer : Nonflammable PP Ø125 5.3
Ø160 5.3
Ø200 6.2
16 dB(A) according to EN 14366.
Fire behavior level is BS2d0 according to EN 13501-1. Fire status is B1
according to DIN 4102.
Up to maximum 95°C long term usage, up to maximum 110°C short term
usage.
Halogen-free.
No Flame Transmission
Suitable for transportation of wastewater (pH” range 2 to 12)
The table below shows the test report results (number P-BA 139/2018e) performed on April 25, 2018
-
for VESBO INCOLA Inferno by Fraunhofer Institute for Building Physics:
Test Results vs. Flow Rates(l/s)
Noise Level Types
0.5 1 2 4
Installation sound level L [dB(A)] measured in the basement test room UG front 43 47 49 52
1
in
Installation sound level L [dB(A)] measured in the basement test room UG rear <10 <10 14 19
1
in
2
Installation sound level L [dB(A)] measured in the basement test room UG front 40 45 47 49
in
2
Installation sound level L [dB(A)] measured in the basement test room UG rear <10 <10 <10 16
in
3
Airborne sound pressure level L a,A [dB(A)] in the basement test room UG front 43 47 49 52
3
Structure-borne sound chracteristic level L sc,A [dB(A)] in the basement test room UG rear <10 <10 11 16
Table 3. Sound Insulation Results for VESBO Incola Inferno in accordance with DIN 4109, VDI 4100 and EN 14366 Standards
Evaluation according to DIN 4109, Evaluation according to VDI, Evaluation according to EN 14366
1 2 3