Page 1 - VESBO ANTI MICROBIAL PRODUCT DATA SHEET
P. 1

®
                                   ®
    Product Specification of PPR BioCote  Anti-Microbial Pipe    Certificate of Antibacterial Analysis – Biocote

                                                                    Sample   Test Organism   Contact Time   Reduction (Initial)
                                                                                     0 hrs.   24 hrs.   Log 10   %
                                                               Pipe PP-R with B65003 at 0.15%   MRSA   2.11E+05   1.00E+03   2.32   99.53%
    Definition                                                 Pipe PP-R with B65003 at 0.15%   E.coli   2.32E+05   ≤11.11   ≥4.32   ≥99.99%

                         ®
    VESBO® PP-R new BioCote  anti-microbial pipe is made with the aid of   Sizes of Product
    innovative  techniques.  Using  VESBO  PP-R  new  BioCote   anti-microbial
                                              ®
    pipe allows you to make the surface of your products more resistant to the   SDR6 / PN20   SDR7.4 / PN16   SDR11 / PN 10
    attack by microbes and bacteria. The adhesion and proliferation of bacteria
                                                                D x s (mm)   D (mm)   s (mm)   D x s (mm)   D (mm)   s (mm)   D x s (mm)   D (mm)   s (mm)
    on the surface of the object are slowed down and the microbes and bacteria
                                                                20 x 3.4   20 -0+0,3   3.4 -0 +0.5   20 x 2.8   20 -0+0,3   2.8 -0 +0.4   20 x 2.0   20 -0+0,3   2.0 -0 +0.3
    count is being strongly reduced by only the mechanical/physical property of
                                                                25 x 4.2   25 -0+0,3   4.2 -0 +0.6   25 x 3.5   25 -0+0,3   2.5 -0 +0.5   25 x 2.3   25 -0+0,3   2.3 -0 +0.4
    the  surface.  Objects  and  products  produced  with  VESBO  PP-R  new   32 x 5.4   32 -0+0,3   5.4 -0 +0.7   32 x 4.4   32 -0+0,3   4.4 -0 +0.6   32 x 2.9   32 -0+0,3   2.9 -0 +0.4
    BioCote  anti-microbial pipe obtains antiseptic and antibacterial properties
          ®
                                                                40 x 6.7   40 -0+0,4   6.7 -0 +0.8   40 x 5.5   40 -0+0,4   5.5 -0 +0.7   40 x 3.7   40 -0+0,4   3.7 -0 +0.5
    proven by test according to ISO 22196 standard.
                                                                50 x 8.3   50 -0+0,5   8.3 -0 +1.0   50 x 6.9   50 -0+0,5   6.9 -0 +0.8   50 x 4.6   50 -0+0,5   4.6 -0 +0.6
                                                                63 x 10.5   63 -0+0,6   10.5 -0 +1.2   63 x 8.6   63 -0+0,6   8.6 -0 +1.0   63 x 5.8   63 -0+0,6   5.8 -0 +0.7
                                                                75 x 12.5   75 -0+0,7   12.5 -0 +1.4   75 x 10.3   75 -0+0,7   10.3 -0 +1.2   75 x 6.8   75 -0+0,7   6.8 -0 +0.8
    Material              :  PP-R  80  Random  Copolymer  with  Anti-  90 x 15.0   90 -0+0,9   15.0 -0 +1.6   90 x 12.3   90 -0+0,9   12.3 -0 +1.4   90 x 8.2   90 -0+0,9   8.2 -0 +1.0
                          Microbial Additives                   110 x 18.3   110 -0+1,0   18.3 -0 +2.0   110 x 15.1   110 -0+1,0   15.1 -0 +1.7   110 x 10.0   110 -0+1,0   10.0 -0 +1.1
                                                                125 x 20.8   125 -0+1,2   20.8 -0 +2.3   125 x 17.1   125 -0+1,2   17.1 -0 +2.0   125 x 11.4   125 -0+1,2   11.4 -0 +1.3
    Pipe Sizes            : 20mm to 160mm                       160 x 26.6   160 -0+1,5   26.6 -0 +2.9   160 x 21.9   160 -0+1,5   21.9 -0 +2.4   160 x 14.6   160 -0+1,5   14.6 -0 +1.7

    Pipe Lengths          : Standard: 4 m; Optional:3-6 m
                                                                Products  protected  by  BioCote  anti-microbial  technology  will  negatively
                                                                                       ®
    Pipe Rating (Pressure Class) : PN10 (S5), PN16 (S3.2), PN20 (S2.5)
                                                                affect bacteria that contaminate the surface through:
    Colour Range          :  White,  Green,  Blue,  Cappuccino,  Grey,
                          Black, Red, Lilac                         •   Protein  Damage:  Proteins  are  essential  for  the  biological
                                                                       systems of life. Any damage to these components causes the
    Density at 23°C       : 0.9 gr/cm³                                 failure of essential functions such as energy production.

    Connection            : Fusion Welding
                                                                    •   Cell  membrane  damage:  By  disrupting  the  membrane  of
    Standards             : ISO 22196                                  microbes,  its  structural  integrity  is  compromised,  which  can
                                                                       cause essential nutrients to leak out and catastrophic structural
    External Audits       : ISO 9001, ISO 14001, HACCP                 failure.

    Registrations         :  CMA  and  CNAS  –  CHINA  P.R,  SKZ,
                          DVGW  and  Hygiene  Institut  -  GERMANY,   •   Oxidative damage: Antimicrobials can cause increased levels
                          ILAC-MRA – GLOBAL, SPAN and SIRIM –          of reactive oxygen species, which result in damage to the internal
                          MALAYSIA, CERTIF – PORTUGAL, SGR –           systems of the microbe.
                          RUSSIA, SGBC – SINGAPORE, AENOR –
                          SPAIN, TSE – TURKEY.
                                                                    •   DNA  interference:  The  genetic  material  of  the  bacteria  is
    Product Application   : Food transportation, drinking water supply,   disrupted,  ultimately  stopping  the  bacteria  from  being  able  to
                          medical products’ transportation             replicate by blocking the copying of their genetic material.


    Advantages
                                                                High Effective Rate Against  :   Staphylococcus   Aureus   (gram+),
        •   Eradicates and reduce the presence of virus, bacteria and mold
            by up to 99.99 %.                                                        Escherichia Coli (E. Coli) (gram-), Methicillin-
        •   Minimize staining and bad odors.                                         Resistant  Staphylococcus  Aureus  (MRSA),
        •   Works during storage and after installation when in use.                 Acinetobacter  Baumannii,  Pseudomonas
        •   Reduce the risks of cross-contamination                                  Aeruginosa,   Enterobacter   Cloacae,
        •   Biocote is one of the only anti-microbial product certified by           Clostridium  Difficile,  Candida  Albicans,
                                                                                                 Listeria,
                                                                                                         Staphylococcus
                                                                                     Salmonella,
            HACCP International’s Food Safety Certification
                                                                                     epidermidis & etc.




                                                     www.vesbo.com
   1