Page 2 - INCOLA EXCLUSIVE DATA SHEET
P. 2

the installation wall. It is advisable to use a single VESBO Acoustic Clamp
    VESBO  INCOLA  Exclusive  pipes  have  very  low  thermal  expansion   System for each floor for sound safety.
    coefficient. However, to ensure pipeline safety, the difference between the
    maximum temperature of the wastewater and the minimum temperature of   A  fastening  clamp  should  be  placed  right  under  the  connection  point
    the  pipes  to  be  installed  should  be  taken  into  consideration  when   surrounding a pipe, and it should be locked and fixed to the pipe in a vertical
    connecting pipes and fittings. In addition, extra measures should be taken   installation. A support  clamp  should  be  placed  right  under  the  fastening
    to  avoid  external  forces  on  connection  points.  During  installation,  it  is   clamp.
    advisable not to insert connection points into one another completely, but
    to leave a 10mm allowance for pipes to expand under heat.   For pipe weights to be carried easily and to avoid slipping at the connection
                                                                points, pipe Support clamps should be used at intervals of 2m for system
                                                                safety.
    Installation
                                                                Clamp intervals  recommended for  vertical  and  horizontal  installations  of
    Connection of pipe and fittings                             VESBO INCOLA Exclusive pipes are listed in the table below.

    VESBO INCOLA Exclusive pipes and fittings have belled ends equipped   Pipe External   Vertical Lines Max.   Horizontal Lines Max.
    with elastomeric gaskets. Applying lubricants on the gaskets will ease the   Diameter (mm)   Support Clamp Interval   Support Clamp Interval
    jointing. Push-fit system provides easy installations even in difficult spaces.   OD   (mm)   10 x Pipe External
                                                                                               Diameter (mm)
    It is strictly not advisable to remove the gaskets during jointing.   50      2000             500
                                                                     75           2000             750
    Dry, unclean or cracked gaskets should not be used in an installation and   110   2000        1100
                                                                     125          2000            1250
    should be replaced with new ones.                                160          2000            1600

    It is important to ensure that the ends of pipes and fittings are entirely safe   For connections between floors, short (500mm) VESBO INCOLA Exclusive
    and clean from dirt and oil before an installation.         pipes should be used. In addition, it is recommended to wrap the pipes
                                                                inside concrete with a noise absorbing, foam-like insulation material.
    VESBO  pipes  and  fittings  are  designed  to  perform  best  as  an  integral
    system and should not be mixed with pipes and fittings of other brands in   Connections Between Vertical and Horizontal Lines
    an installation.
                                                                The amount of sound generated mostly depends on the length of the pipe.
    Cutting the Pipes                                           For connections between vertical and horizontal lines, it is recommended
                                                                to use two VESBO INCOLA Exclusive 45° Elbows instead of a single 87°
    VESBO INCOLA Exclusive pipes may be cut by using a rotary pipe cutter
    or a sharp saw that has a thin cutter head. Cracks or breaks on the cut   Elbow. A 25cm long VESBO INCOLA Exclusive pipe should be placed in
    piece must be carefully checked. Avoid pressing on the pipe while cutting   between the two 45° Elbows.
    to prevent it from getting deformed.
                                                                Installation at Horizontal Lines
    VESBO INCOLA Exclusive pipes should be cut at a 90° angle to the pipe
    axis. After cutting, burrs on the edges should be cleaned off. For ease of   It is not necessary to use the double clamping system on horizontal lines.
    installation and to avoid slipping of the gasket, chamfering to pipe edges   To fix pipes to the walls, it is recommended to use only pipe support clamps
    (approximately15°) is recommended.                          right after the belled-end parts next to the joints with intervals of 10xOD (10
                                                                times the external diameter of the pipe).

    Installation in Vertical Lines                              Installation of Pipes Inside Concrete

    The right clamps play a crucial role in sound proofing. In vertical lines it is   Lines  in  kitchens  and  bathrooms  can  be  concealed  in  concrete.  We
    recommended to use specially designed and patented VESBO Acoustic   recommend to wrap the lines with insulating materials in order to avoid their
    Clamp System together with VESBO INCOLA Exclusive pipes and fittings   direct contact to concrete.
    for  the  best  sound  insulation  results.  VESBO  Acoustic  Clamp  System
    consists of a double clamping system comprising a fastening clamp and a   Make  sure  that  the  lines  are  properly  aligned  and  the  joints  will  not  be
    support  clamp.  Specially  designed  air  channeled  rubber  gasket  on  the   disrupted while plastering.
    fastening clamp prevents the sound from reaching the wall because of its
    vibration absorbing layer by using the support clamps, pipes are fixed onto   Keep the installation area clean, do not leave any sharp objects that may
                                                                damage the pipes and fittings.








                                                     www.vesbo.com
   1   2   3