Page 1 - VESBO PE-RT PRODUCT DATA SHEET
P. 1
Product Specification of PERT & PERT Pipe with Standard : DIN 16833, ISO 22391
Oxygen Barrier
Hot & Cold Water Piping System Rules to be Followed During Installation
Definition Pipes are installed using a special welding machine. The
temperature of the place where the installation is done, should
VESBO PERT pipes are manufactured from raised temperature
polyethylene with advanced polymeric structure which makes them the best be under the 10°C.
solution for a wide range of liquid transportation. The advantages of VESBO It is not allowed to distort and break the pipeline during assembly.
PERT over other plastic and metal piping systems, such as high operation Pipes that are transported and stored under 0 ° C, should be kept
temperatures, non-corrosiveness, flexibility, higher impact strength at lower at a temperature not exceeding 10 ° C for 24 hours before being
temperatures and speed of installation, are considered the main reasons transferred to production.
for being preferred by engineers for residential and industrial projects. Pipe ends should be closed with plugs to prevent pipe
contamination and dusting.
When bending the pipe (maximum radius of 5D outside), it is
recommended to preheat the pipe to 130 ° C with a dryer. The
Material : Raised temperature polyethylene (PE) with pipe must be bent using a spring conductor.
advanced polymeric structure
When heating the pipe, the pipe should be fixed to rotating points
and 10 cm gap should be left with clamps to prevent the bent part
Pipe Sizes : 16mm, 17mm, 20mm, 25mm, 32mm
from flattening.
Density : 0.94 g/cm³ (DIN 53497) Underfloor heating pipeline should be closed with concrete or
other coating after hydraulic tests are done. Coating height
Application and Usage Area : Radiator connections, outdoor snow should not be less than 3 cm.
melting, district heating / cooling, under-floor & wall heating, radiant heating Fixed supporting connections on the pipeline should be properly
and cooling systems, hot and cold water plumbing applications; residential installed.
and commercial The pipe should be protected from direct sunlight.
Pipe Dimension and General Properties
D, Pipe S, Wall Standard Nominal Class Info. for
Diameter Thickness Dimension Pressure Hot water Application Coil/Length (m) Usage and Technical Maintenance Rules
(mm) (mm) Ratio
PERT pipes should not be used in the following situations:
2.0 SDR 9 PN 16 1/8; 2/8; 4/10; 5/8
16 160, 200, 400,500, 600
2.2 SDR 7.4 PN 20 1/10; 2/10; 4/10; 5/8
at operating temperature of the liquid carried above -
17 2.0 SDR 8.5 PN 16 1/8; 2/8; 4/10; 5/8 160, 200, 400,500, 600
130 ° C,
2.0 SDR 11 PN 12.5 1/6; 2/6; 4/8; 5/6
20 160, 200, 400, 500 at operating pressure of 10 bar,
2.8 SDR 7.4 PN 20 1/10; 2/10; 4/10; 5/10 in thermal radiation source areas whose surface
25 2.3 SDR 11 PN 12.5 1/6; 2/6; 4/8; 5/6 160, 200 temperature exceeds 150 ° C;
32 2.9 SDR 11 PN 12.5 1/6; 2/6; 4/8; 5/6 160, 200 in safety (security), transmission and signaling piping
systems
Table 1. Polyethylene of Raised Temperature Resistance Pipes (PERT)
D, Pipe S, Wall Standard
Nominal
Class Info. for
Diameter Thickness Dimension Pressure Hot water Application Coil/Length (m)
(mm) (mm) Ratio
2.0 SDR 9 PN 16 1/8; 2/8; 4/10; 5/8
16 160, 200, 400,500, 600
2.2 SDR 7.4 PN 20 1/10; 2/10; 4/10; 5/8
32 2.9 SDR 11 PN 12.5 1/6; 2/6; 4/8; 5/6 160, 200
Table 2. Pipe - In- Pipe PERT
www.vesbo.com