Page 1 - VESBO PE-RT PRODUCT DATA SHEET
P. 1

Product Specification of PERT & PERT Pipe with              Standard             : DIN 16833, ISO 22391
    Oxygen Barrier

    Hot & Cold Water Piping System                              Rules to be Followed During Installation
    Definition                                                         Pipes  are  installed  using  a  special  welding  machine.  The
                                                                       temperature of the place where the installation is done, should
    VESBO  PERT  pipes  are  manufactured  from  raised  temperature
    polyethylene with advanced polymeric structure which makes them the best   be under the 10°C.
    solution for a wide range of liquid transportation. The advantages of VESBO      It is not allowed to distort and break the pipeline during assembly.
    PERT over other plastic and metal piping systems, such as high operation      Pipes that are transported and stored under 0 ° C, should be kept
    temperatures, non-corrosiveness, flexibility, higher impact strength at lower   at a temperature not exceeding 10 ° C for 24 hours before being
    temperatures and speed of installation, are considered the main reasons   transferred to production.
    for being preferred by engineers for residential and industrial projects.       Pipe  ends  should  be  closed  with  plugs  to  prevent  pipe
                                                                       contamination and dusting.
                                                                       When  bending  the  pipe  (maximum  radius  of  5D  outside),  it  is
                                                                       recommended to preheat the pipe to 130 ° C with a dryer. The
    Material              : Raised temperature polyethylene (PE) with   pipe must be bent using a spring conductor.
                          advanced polymeric structure
                                                                       When heating the pipe, the pipe should be fixed to rotating points
                                                                       and 10 cm gap should be left with clamps to prevent the bent part
    Pipe Sizes            : 16mm, 17mm, 20mm, 25mm, 32mm
                                                                       from flattening.
    Density               : 0.94 g/cm³ (DIN 53497)                     Underfloor  heating  pipeline  should  be  closed  with  concrete  or
                                                                       other  coating  after  hydraulic  tests  are  done.  Coating  height
    Application and Usage Area  :  Radiator  connections,  outdoor  snow   should not be less than 3 cm.
    melting, district heating / cooling, under-floor & wall heating, radiant heating      Fixed supporting connections on the pipeline should be properly
    and cooling systems, hot and cold water plumbing applications; residential   installed.
    and commercial                                                     The pipe should be protected from direct sunlight.

    Pipe Dimension and General Properties

      D, Pipe   S, Wall   Standard   Nominal   Class Info. for
     Diameter   Thickness   Dimension   Pressure   Hot water Application   Coil/Length (m)   Usage and Technical Maintenance Rules
      (mm)   (mm)   Ratio
                                                                PERT pipes should not be used in the following situations:
             2.0   SDR 9   PN 16   1/8; 2/8; 4/10; 5/8
       16                                 160, 200, 400,500, 600
             2.2   SDR 7.4   PN 20   1/10; 2/10; 4/10; 5/8
                                                                              at operating temperature of the liquid carried above -
       17    2.0   SDR 8.5   PN 16   1/8; 2/8; 4/10; 5/8   160, 200, 400,500, 600
                                                                              130 ° C,
             2.0   SDR 11   PN 12.5   1/6; 2/6; 4/8; 5/6
       20                                 160, 200, 400, 500                  at operating pressure of 10 bar,
             2.8   SDR 7.4   PN 20   1/10; 2/10; 4/10; 5/10                   in thermal radiation source areas whose surface
       25    2.3   SDR 11   PN 12.5   1/6; 2/6; 4/8; 5/6   160, 200           temperature exceeds 150 ° C;
       32    2.9   SDR 11   PN 12.5   1/6; 2/6; 4/8; 5/6   160, 200           in safety (security), transmission and signaling piping
                                                                              systems


      Table 1. Polyethylene of Raised Temperature Resistance Pipes (PERT)

      D, Pipe   S, Wall   Standard
                        Nominal
                                Class Info. for
     Diameter   Thickness   Dimension   Pressure   Hot water Application   Coil/Length (m)
      (mm)   (mm)   Ratio
             2.0   SDR 9   PN 16   1/8; 2/8; 4/10; 5/8
       16                                 160, 200, 400,500, 600
             2.2   SDR 7.4   PN 20   1/10; 2/10; 4/10; 5/8
       32    2.9   SDR 11   PN 12.5   1/6; 2/6; 4/8; 5/6   160, 200

      Table 2. Pipe - In- Pipe PERT








                                                     www.vesbo.com