Page 16 - INCOLA EXCLUSIVE DATA CATALOGUE
P. 16

Sound Insulation






                2.4.2 VDI 4100 - Sound Safety in Houses – Criteria for Planning and Evaluation



                The Association of German Engineers (VDI) has more than 150,000 engineers and naturalist
                members. With more than 12,000 honorary members, every year the Association promotes the
                advancement of technology to develop the latest findings.

                In addition to the sound insulation requirements of the sections specified in DIN 4109, VDI 4100
                defines the best sound insulation levels between rooms in terms of privacy and higher comfort
                in residences or residential-like buildings.

                VDI 4100 Regulation consists of enlarged noise protection demands and covers three sound
                safety levels:



                • Apartment flats
                • Duplex, detached and attached houses
                • Buildings


                VDI  4100  Regulation  is  not  legally  binding,  but  provides  guidance  in  addition  to  legal
                regulations. This regulation is widely accepted by experts.





                  Noise Security
                                                                     Definition
                  Levels (SSt)
                                  Describes an acoustically justified niveau of dwellings based on a low background noise level, where
                       I          annoyances in neighbouring dwellings are reduced on a reasonable and acceptable degree.
                                  For example to be expected for a dwelling, which is also sufficient in its other construction, design and
                       II         related outfit for the average require-ments of comfort measures.
                                  For example to be expected for a dwelling, which also in its other construction and related outfit as well as
                       III
                                  in its site is sufficient for special comfort measures.
                Table 6. System Definitions of VDI 4100



                Three different sound protection levels are defined for VDI 4100. Since SSt III represents the
                level of highest comfort, it includes the most strict requirements.




                  Noise Security                              Duplex, detached, and
                                    Apartment Flats                                           Buildings
                  Level (SSt)                                 semi-attached houses

                       I                ≤ 30 dB(A) 1                 ≤ 30 dB(A) 1             ≤ 30 dB(A)
                       II                ≤ 27 dB(A)                  ≤ 25 dB(A)               ≤ 30 dB(A)

                       III               ≤ 24 dB(A)                  ≤ 22 dB(A)               ≤ 30 dB(A)


                Table 7. Noise Levels in Accordance with the VDI Regulations
                1   Same with DIN 4109.