Page 36 - INCOLA EXCLUSIVE DATA CATALOGUE
P. 36
System Performance
4.3.3 System Performance Applicable to INCOLA Inferno According to
EN 1451-1
Test Standard Condition Result Suitability
Pipe with Socket
For raw material;
Melt Flow Rate EN ISO 1133-1 Max.: 3g/10 min. 0.30 g/10 min. -
(230°C / 2.16 kg) SUITABLE
0.39 g/10 min.
Impact Resistance EN ISO 3127 should have no damage no cracking observed in SUITABLE
(24 h/0 °C) Tolerance : %10 any of the 10 testers
Longitudinal Reversion
(150 ° /60 min.) EN ISO 2505 Max.: %2 ≤ % 0.85 SUITABLE
Ring Stiffness EN ISO 9969 Min.: 4 kN/m² ≥ 4 kN/m² SUITABLE
Resistance to the
Internal Pressure Test EN ISO 1167-1 should have no damage - SUITABLE
( 95°C - 2.5 MPa - 100h) EN ISO 1167-2
( 80°C - 4.2 MPa - 140h)
Water Tightness EN ISO 13254 should be impermeable - SUITABLE
Air Tightness EN ISO 13255 should be impermeable - SUITABLE
should be impermeable
High Temperature EN ISO 13257 Deviation <0.05dn or -
Cycling Test 3 mm (whichever is SUITABLE
smaller)
Tightness of elastromeric Condition B: with
EN 1277 SUITABLE
ring seal joints-BD deformation of the pipe -
DIN 4102 - B1
Non-combustibility Level SUITABLE
EN 13501-1 - BS2d0
Sound Transmission
DIN 4109 ≤ 30 dB(A) 16dB(A)
Level SUITABLE
Material Polypropylene with mineral
additive