Page 27 - INCOLA EXCLUSIVE DATA CATALOGUE
P. 27

INCOLA Soundproof Piping Systems






                3.2.  EN 13501-1 Fire Classication of Construction Products and
                      Building Elements - Classication Using Data from Reaction to
                      Fire Tests


                This standard determines the fire classification procedure for building elements and all other
                products and is directly related to the SBI (Single Burning Item) test applied in EN-13823 + A1
                (fire response tests for building products).


                This  European  Standard  covers  the  processes  of  classifying  the  behavior  of  all  building
                products against flame, including products used in conjunction with building elements. The
                products are taken into consideration with regards to their end use. In this standard, building
                products are considered in three different groups.
                ·   Construction products, excluding floorings and linear pipe thermal insulation products;
                ·   Floorings;
                ·   Linear pipe thermal insulation products.

                  Flammability of   No Smoke  No Combustion   European Class
                     Material   Generation Drips/Particles  (Acc.to EN EN   Reaction Class to Fire acc.to DIN 4102
                                                           13501-1)
                                                                                         A1
                 Not Flammable      X          X             A1       (Sand, gravel, gypsum, concrete, brick, ceramic, glass
                                                                                 wool, rock wool, perlite)
                                                                                         A2
                 Hardly Flammable   X          X           A2-s1,d0     ( Glass wool and stone wool with organic binding)
                                                           B-s1,d0
                                    X          X
                                                           C-s1,d0
                                                           A2-s2,d0
                                                           A2-s3,d0
                                               X           B-s2,d0
                                                           B-s3,d0
                                                                                         B1
                                                           C-s2,d0
                                                                            (Gypsum-cardboard plate, cement wood
                 Hardly Flaming                            C-s3,d0
                                                           A2-s1,d1         shavings, polystyrene and polyurethane
                                                           A2-s1,d2      foam-sandwich panel with fire retardant additive)
                                                           B-s1,d1
                                    X
                                                           B-s1,d2
                                                           C-s1,d1
                                                           C-s1,d2
                                                           A2-s3,d2
                                                           B-s3,d2
                                                           C-s3,D2
                                                           D-s1,d0
                                                           D-s2,d0
                                               X
                                                           D-s3,d0
                                                             E
                                                           D,s1,d1                       B2
                                                           D-s2,d1
                                                                            (Wood silicone joint filler, polystyrene
                 Normal Flaming                            D-s3,d1
                                                                                 and polyurethane foam)
                                                           D,s1,d2
                                                           D-s2,d2
                                                           D-s3,d2
                                                            E-d2
                                                                                         B3
                 Easy Flaming                                F                 ( Wood shavings, paper esc.)
                Table 10. Classes of reaction to fire performance according to DIN 4102 and EN 13501-1
                2  The Single Burning Item (SBI), is a method of test for determining the reaction to fire behavior of building products (excluding floorings) when exposed
                to the thermal attack by a single burning item (a sand-box burner supplied with propane).
                                                           25
   22   23   24   25   26   27   28   29   30   31   32